UN-7001-LAC Static Hydraulic Universal Testing Machine
Previous | 2 / 9 | Next |
Model | UN-7001-LAC200 | UN-7001-LAC100 | UN-7001-LAC50 | UN-7001-LAC30 | UN-7001-LAC20 | UN-7001-LAC10 | ||
PC based | 200tf | 100tf | 50tf | 30tf | 20tf | 10tf | ||
Speed(without loading) | 0.01~65 | 0.01~70 | 0.01~70 | 0.01~90 | 0.01~90 | 0.01~90 | ||
Display Method |
By Computer
|
|||||||
Load Range |
Rangeless(full scales at the same amplification)
|
|||||||
Resolution |
1/500000
|
|||||||
Load Accuracy |
±1%
|
|||||||
Driving Method |
Hydraulic System
|
|||||||
Tensile | Max. Space | 520 | 370 | 370 | 360 | 360 | 360 | |
Grips for Rod(rod dia.) | 12~85 | 13~75 | 12~50 | 10~40 | 10~40 | 10~40 | ||
Grips for Plate | 85x110 | 70x90 | 50x80 | 40x60 | 40x60 | 40x60 | ||
Compression | Effective Space(2) | 750 | 590 | 590 | 560 | 560 | 560 | |
Diameter of Compression Platen | 200 | 170 | 120 | 100 | 100 | 100 | ||
Transverse | Effective Space(3) | 230 | 190 | 220 | 200 | 200 | 200 | |
Supports | Max. Space (between two fulcrums) | 790 | 340 | 390 | 390 | 390 | 390 | |
Fulcrum Size (dia×width) |
30x210 | 30x145 | 30x145 | 30x145 | 30x145 | 30x145 | ||
Punch |
Radius of Punch |
R35 | R22 | R22 | R16 | R16 | R16 | |
Punch Width |
200 | 160 | 120 | 100 | 100 | 100 | ||
Ram Stroke | 230 | 220 | 220 | 200 | 200 | 200 | ||
Number of pillars | 6 | 6 | 6 | 6 | 6 | 6 | ||
Effective Space (between two columns) | 630 | 450 | 450 | 410 | 410 | 410 | ||
Crosshead drive system |
Hydraulic based
|
|||||||
Crosshead Speed |
300+/-10%
|
|||||||
Dimension(W×D×H) | Main Unit(mm) | 1320X1080X3150 | 1060X830X2600 | 950X750X2300 | 850X660X1950 | 850X660X1950 | 850X660X1950 | |
Control Uni(mm)t | 1270X760X990 | 1270X760X990 | 1270X760X990 | 1270X760X990 | 1270X760X990 | 1270X760X990 | ||
Standard accessories |
Plate and rod grips
|
|||||||
Optional accessories |
Bending jig , Compression platens
|